FW V06.02.00/HAFM SW V08.02.00 HP StorageWorks Edge Switch Release Notes (AA-RTDZF-TE, September 2004)

Table Of Contents
About this document
15HP StorageWorks Edge Switch release notes
Zoning change RSCN control
Normally, when a zone set is activated, a fabric format domain Register State
Change Notification (RSCN) is sent to all devices in the fabric. With firmware
05.00.00 or later, you can disable these RSCNs from being sent. This is done
using the Suppress RSCNs on zone set activations check box on the Configure
Switch Parameters dialog box.
This feature significantly changes the normal behavior of the fabric. Devices will
have no warning when zones change and will not automatically update their
zoning information. The ability to suppress RSCNs is disabled (check box is not
selected) by default. This feature can be configured through HAFM, EWS, and
CLI.
SNMP changes
Firmware 06.02.00-22 supports the following management information base
(MIB) versions on all products:
Fabric Element MIB: 1.1
MIB-II MIB: RFC-1213, non-implemented sections are not included
FCEOS MIB: 2.0
SNMP Framework MIB: RFC-2271 (1997/09/30)
FA MIB: 3.0
FA MIB: 3.1
SNMP requests can be received in either 3.0 or 3.1 of the Fibre Alliance (FA)
MIB, and the switch responds in the same version. The switch can also be
configured to use a specific version for traps generated by the switch.
Zoning limitations
With firmware 06.00.00 and later, you have the ability to configure large zone
sets, including up to 1024 zones and 1024 end ports in a single zone set. Table 2
shows the supported limits for the edge switches and directors.