Table Of Contents
- Edge Switch release notes
- About this document
- Release notes information
- Intended audience
- Firmware version 06.02.00-22
- Other edge switch documentation
- CD-ROM directory structure
- Supported configurations
- Cable requirements
- Important information
- HAFM and firmware compatibility
- Prerequisites for installing and using firmware 06.02.00
- Upgrading from an earlier version of firmware
- Upgrading firmware on an edge switch from 04.xx.xx to 05.xx.xx
- Considerations for downgrading the version of firmware
- HAFM upgrade required for firmware version 06.xx.xx
- Second-generation switch support
- OSMS change
- Default zone is disabled by default
- Some IP addresses must be avoided
- Hard zoning
- Zoning change RSCN control
- SNMP changes
- Zoning limitations
- Using the same firmware
- Reinstalling feature licenses
- Disconnecting the null modem cable
- CTP controls port lights
- Ethernet switch support
- Full Volatility
- CLI threshold alerts
- CLI show.eventLog command
- MIHPTO value
- Route management-Preferred Path
- EWS enhancements
- Full-fabric capability for Edge Switch 2/12
- Hard zoning for Edge Switch 2/12 and Edge Switch 2/24 switch loop ports
- Known issues
- Certain unauthorized devices may increase response time for fabric operations under specific conditions with the Edge Switch 2/24
- HSG80 transparent mode not supported with IBM AIX
- HSG80 transparent mode not recommended with controller in SCSI-3 mode with HP-UX operating systems
- ISL disconnect causes NOS error with the OpenVMS operating systems
- Support for speed Auto-Negotiate
- Ports may accumulate spurious events
- Possible switch reset after power failure or power off sequence
- Deleting a certain switch binding member using EWS may cause an error
- SNMP issues
About this document
5HP StorageWorks Edge Switch release notes
■ HP StorageWorks Edge Switch 2/32 Installation Guide,
AA-RSTZD-TE/958-000290-002
■ HP StorageWorks Edge Switch 2/32 Service Manual, AA-RS2GD-TE
■ HP StorageWorks CLI Reference Guide for Directors and Edge Switches,
AA-RQ7AE-TE
■ HP StorageWorks SNMP Reference Guide for Directors and Edge Switches,
AA-RQ7BE-TE
■ HP StorageWorks SAN High Availability Planning Guide, AA-RS2DD-TE
■ HP StorageWorks SAN Design Guide, AA-RMPNN-TE
■ HP StorageWorks Embedded Web Server User Guide, AA-RTDRC-TE
■ HP StorageWorks HA-Fabric Manager User Guide, AA-RS2CE-TE
■ HP StorageWorks HA-Fabric Manager Transition Guide, AA-RV1MA-TE
■ HP StorageWorks HA-Fabric Manager Appliance Installation Guide,
AA-RU5FB-TE/958-000324-001
■ HP StorageWorks HA-Fabric Manager Release Notes,
AA-RUR6D-TE/958-000288-008
■ HP StorageWorks Director and Edge Switch Glossary, AA-RU5JB-TE
■ HP StorageWorks C-FCSWAPI SDK Bridge Agent Installation Instructions,
AA-RVJ1A-TE/958-000405-000
CD-ROM directory structure
The HP StorageWorks edge switch documentation and firmware CD contains the
following items:
■ Manuals.pdf—HP StorageWorks Edge Switch 2/12, Edge Switch 2/24,
and Edge Switch 2/32 Documentation; links to the following documents and
search function
■ Documents
— README.TXT—HP document structure; late-breaking doc changes
— AA-RV14C-TE/958-000339-002—HP StorageWorks Edge Switch 2/12
Flexport Upgrade Instructions
— AA-RURCB-TE/958-000340-001—HP StorageWorks Edge Switch 2/12
Installation Guide
— AA-RURDB-TE—HP StorageWorks Edge Switch 2/12 Service Manual