FW 08.01.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-330, November 2005)
Maintenance Analysis Procedures
3-29
Maintenence Analysis Procedures
Ta bl e 3 -1 0 lists link incident messages and MAP steps.
506 Fibre Channel port failure. Go to step 17.
507 Loopback diagnostics port failure. Go to step 18.
512 Optical transceiver nonfatal error. Go to step 17.
514 Optical transceiver failure. Go to step 17.
515 Optical digital diagnostics warning threshold exceeded. Go to step 17.
516 Optical digital diagnostics alarm threshold exceeded. Go to step 17.
581 Implicit incident. Go to step 19.
582 Bit error threshold exceeded. Go to step 19.
583 Loss of signal or loss of synchronization. Go to step 19.
584 Not operational primitive sequence received. Go to step 19.
585 Primitive sequence timeout. Go to step 19.
586 Invalid primitive sequence received for current link state. Go to step 19.
Table 3-10 Link Incident Messages
Explanation Action
Link interface incident - implicit incident. Go to step 19.
Link interface incident - bit-error threshold exceeded. Go to step 19.
Link failure - loss of signal or loss of synchronization. Go to step 19.
Link failure - not-operational primitive sequence (NOS) received. Go to step 19.
Link failure - primitive sequence timeout. Go to step 19.
Link failure - invalid primitive sequence received for current link state. Go to step 19.
Table 3-9 MAP 500 Event Codes (Continued)
Event
Code
Explanation Action