edge switch 2/32 product manager user guide
edge switch 2/32 product manager user guide 2–11
Monitoring and Managing the Switch
• 03 ELP rejected by the attached switch — This Director/Switch transmitted an
exchange link protocol (ELP) frame that was rejected by the Switch at the other
end of the ISL.
• 04 Incompatible switch at the other end of the ISL — Interop mode for this
Switch is set to Open Fabric mode and the Switch at the other end of the ISL is a
HP Switch configured for Homogeneous Fabric mode.
• 05 External loopback adapter connected to the port. — A loopback plug. is
connected to the port and there is no diagnostic test running.
• 06 N_Port connection not allowed on this port — The port type configuration
does not match the actual port use. Port is configured as an E_Port, but attaches to
a node device.
• 07 Non-HP switch at other end of the ISL — The cable is connected to a
non-HP Switch and interop mode is set to Homogeneous fabric mode.
• 08 ISL connection not allowed on this port — The port type configuration does
not match the actual port use (the port is configured as an F_Port, but attaches to a
Switch or Director).
• 10 Port binding violation - unauthorized WWN — The WWN entered to
configure port binding is not valid or a nickname was used that is not configured
through the Product Manager for the attached device.
• 11 Unresponsive node connected to port — Possible causes are:
— Hardware problem on Switch or on a connected node where ELP frames are
not delivered, the response is not received, or a fabric login in (FLOGI) cannot
be received. There may be problems in Switch SBAR.
— Faulty or dirty cable connection.
— Faulty host bus adapters that do not send out FLOGI within reasonable
timeframe.
Segmented E_Port Messages:
• Incompatible operating parameters, such as resource allocation time-out
values (R_A_TOV) or error-detect time-out values (E_D_TOV) are
inconsistent. Refer to Configure Switch Operating Parameters on page 3–3 for
more information.
• Duplicate domain IDs. Refer to Domain ID on page 3–4 for more information.
• Incompatible zoning configurations. Refer to sections on joining zoned fabrics
in the hp StorageWorks edge switch 2/32 service manual and the hp StorageWorks
ha-fabric manager user guide for details.