edge switch 2/32 product manager user guide

2–38 edge switch 2/32 product manager user guide
Monitoring and Managing the Switch
Offline Off Off None The Switch port was configured as
“blocked” and is transmitting the Fibre
Channel OLS to the attached device.
Off Off Yellow
Triangle
The Switch port was configured as
“Unblocked” and is receiving the Fibre
Channel OLS, indicating that the
attached device is offline.
Port Failure Off On Red and
Yellow
Blinking
Diamond
The Switch port has failed and requires
service. The amber LED for the port
remains illuminated.
Segmented
E_Port
On Off Yellow
Triangle
The E_Port is segmented preventing the
two fabrics from joining (this only occurs
when two Switches are connected to
each other). Display the Port Properties
dialog box to view the segmentation
reason.
Testing Off Blink Yellow
Triangle
Port is executing an internal loopback
test.
On Blink Yellow
Triangle
Port is executing an external loopback
test.
Note: For any loopback test, the amber
LED blinks (beacons) to help users
locate the port under test.
Not
Installed
Off Off Yellow
Triangle
The port optics are not installed or the
feature that provides additional port
function is not enabled.
a. The alert indicator displays on the port in the Hardware view. It indicates that a corrective action is
required to return the port to a normal operating state.
Table 2–1: Port States and Indicators (Continued)
Port State
Port Indicators
Alert
Indicator
a
DescriptionGreen Amber