Verify that connectors interfacing with the edge switch 2/32 use LC Duplex
connectors with a PC finish. In addition, the connector at the opposite end of the cable
must use either LC or SC type, depending on the requirements of the connected
device.
Known Issues
This section describes the known issues related to the edge switch 2/32.
HSG80 Transparent Mode Not Supported with IBM AIX
Use of an HSG80 with IBM AIX is restricted to operating the HSG80 in Multibus
mode with the edge switch 2/32. Transparent mode is not supported at this time.
Workaround
None.
HSG80 Transparent Mode Not Recommended with Controller
in SCSI-3 Mode with HP-UX Operating Systems
Due to an issue with non-existent duplicate LUNs being displayed with the HP-UX
operating systems, the HSG80 controller is restricted to SCSI-2 mode of operation
when set to Transparent failover mode.
SCSI-3 mode of operation in Multibus failover mode is fully supported with the use of
Secure Path software, Version 3.0.
Workaround