Fabric Watch Administrator's Guide v6.4.0 (53-1001770-01, June 2010)

110 Fabric Watch Administrator’s Guide
53-1001770-01
Configuring port fencing using the fwConfigure command
A
5. Select advanced configuration by entering 4 at the Select an area = > prompt.
1 : refresh
2 : disable a threshold
3 : enable a threshold
4 : advanced configuration
5 : return to previous page
Select an area => : (1..5) [5] 4
6. Select change above alarm by entering 14 at the Select choice prompt.
1 : change behavior type 11 : change threshold alarm level
2 : change behavior interval 12 : change changed alarm
3 : change threshold boundary level 13 : change below alarm
4 : change custom unit 14 : change above alarm
5 : change custom time base 15 : change inBetween alarm
6 : change custom low 16 : apply threshold alarm changes
7 : change custom high 17 : cancel threshold alarm changes
8 : change custom buffer 18 : return to previous page
9 : apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18] 14
7. Set the alarm for Port Fencing (32) by entering 32 at the Enter above alarm matrix = > prompt.
Errlog-1, SnmpTrap-2, PortLogLock-4
RapiTrap-8, EmailAlert-16, PortFencing-32
Valid alarm matrix is 63
Enter above alarm matrix => : (0..63) [0] 32
8. Verify that the alarm matrix displays the Above Custom as 32, and then change the Threshold
alarm level to custom by entering 11.
1 : change behavior type 11 : change threshold alarm level
2 : change behavior interval 12 : change changed alarm
3 : change threshold boundary level 13 : change below alarm
4 : change custom unit 14 : change above alarm
5 : change custom time base 15 : change inBetween alarm
6 : change custom low 16 : apply threshold alarm changes
7 : change custom high 17 : cancel threshold alarm changes
8 : change custom buffer 18 : return to previous page
9 : apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18] 11
1 : Default
2 : custom
Enter alarm level type => : (1..2) [1] 2
9. Select custom by entering 2 at the Enter alarm level type = > prompt.