TABLE 32 Advanced configuration options using the fwConfigure command
Option Effect Input information
change behavior type Changes the behavior type of a single
element to either Triggered or
Continuous. The change is volatile
because this option is not saved to
flash memory. Every time the switch
is rebooted, this option is reset.
The element index and the required
behavior type
change behavior interval Changes the behavior interval for a
single element. The change is volatile
because this option is not saved to
flash memory. Every time the switch
is rebooted, this option is reset.
This value is effective only when the
behavior type is set to Continuous.
The element index and the required
behavior interval, in seconds
change threshold boundary
level
Changes between the factory default
and custom threshold information.
The required threshold column
change custom unit Obsolete Obsolete
change custom time base Changes the time base for the area,
but only affects the custom column.
The required time base
change custom low Changes the low setting for the
threshold, but only affects the custom
column.
The required low threshold, in the units
defined by the area
change custom high Changes the high setting for the
threshold, but only affects the custom
column.
The required high threshold, in the units
defined by the area
change custom buffer Changes the buffer size for the
threshold, but only affects the custom
column.
The required buffer size, in the units
defined by the area
apply threshold boundary
changes
Confirms the changes made to the
threshold information. This must be
done to retain the changes made.
None
cancel threshold boundary
changes
Returns the boundary information to
the last confirmed state.
None
change threshold alarm level Changes between the factory default
and custom event settings for the
area.
The required event setting column
change changed alarm Changes the notification method for
changed event occurrences for this
method, but only affects the custom
column.
The required notification methods
change above alarm Changes the notification method for
above event occurrences for this
method, but only affects the custom
column.
The required notification methods
change below alarm Changes the notification method for
below event occurrences for this
method, but only affects the custom
column.
The required notification methods