Advanced options using the fwConfigure command
A
To assign the notification method a value, follow these steps:
1. From the area menu, select 4 (advanced configuration) from the area menu.
2. Add the numbers beside each state that you want to include using the values in Table 33.
Enter the total at the prompt.
1 : change behavior type 11 : change threshold alarm level
2 : change behavior interval 12 : change changed alarm
3 : change threshold boundary level13 : change belowalarm
4 : change custom unit 14 : change abovealarm
5 : change custom timebase 15 : change inBetween alarm
6 : change custom low 16 : apply threshold alarm changes
7 : change custom high 17 : cancel threshold alarm changes
8 : change custom buffer 18 : return to previous page
9 : apply threshold boundary changes
10: cancel threshold boundary changes
Select choice => : (1..18) [18]14
Errlog-1, SnmpTrap-2, PortLogLock-4
RapiTrap-8, EmailAlert-16 PortFencing - 31
Valid alarm matrix is 63
Enter above alarm matrix => : (0..63) [0] 35
Index ThresholdName BehaviorType BehaviorInt
216 eportRXPerf216 Triggered 1
217 eportRXPerf217 Triggered 1
218 eportRXPerf218 Triggered 1
219 eportRXPerf219 Triggered 1
220 eportRXPerf220 Triggered 1
221 eportRXPerf221 Triggered 1
222 eportRXPerf222 Triggered 1
223 eportRXPerf223 Triggered 1
Threshold boundary level is setat : Custom
DefaultCustom
Unit Percentage(%) Percentage(%)
Time base minuteminute
Low 0 0
High 100 80
BufSize 0 0
Threshold alarmlevel is set at: Default
Errlog-1, SnmpTrap-2, PortLogLock-4
RapiTrap-8, EmailAlert-16