Fabric Watch Administrator's Guide v6.4.0 (53-1001770-01, June 2010)

Fabric Watch Administrator’s Guide 21
53-1001770-01
Threshold triggers
2
Fabric Watch alarm behavior
Fabric Watch alarm behavior depends on the threshold states associated with the Above, Below
and Changed thresholds. Threshold states can be INFORMATIVE, IN_RANGE, and OUT_OF_RANGE.
Notifications are generated only for the following transitions:
IN_RANGE to OUT_OF_RANGE
OUT_OF_RANGE to IN_RANGE
No alarm is generated for INFORMATIVE to IN_RANGE (or IN_RANGE to INFORMATIVE).