Fabric Watch Administrator's Guide v6.4.0 (53-1001770-01, June 2010)

Fabric Watch Administrator’s Guide 43
53-1001770-01
Fabric monitoring guidelines and default settings
6
Fabric class default settings
Table 4 provides default settings for areas in the Fabric class.
TABLE 4 Fabric class default settings
Area Description Default threshold
settings
Default alarm settings Threshold state
Domain ID Changes Monitors forcible
DOMAIN ID changes
Unit: D_ID Changes
Time Base: none
Low: 0
High: 0
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
Loss of E_Port Monitors E_Port and
VE_Port status
Unit: Downs
Time Base: none
Low: 0
High: 0
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
Fabric Logins Monitors host device
fabric logins
Unit: Logins
Time Base: none
Low: 0
High: 0
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
Fabric
Reconfiguration
Monitors
configuration
changes
Unit: Reconfigs
Time Base: none
Low: 0
High: 0
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
Segmentation
Changes
Monitors
segmentation
changes
Unit: Segmentations
Time Base: none
Low: 0
High: 0
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
Zoning Changes Monitors changes to
currently enabled
zoning
configurations
Unit: Zone changes
Time Base: none
Low: 0
High: 0
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative