Fabric Watch Administrator's Guide v6.4.0 (53-1001770-01, June 2010)

Fabric Watch Administrator’s Guide 47
53-1001770-01
SFP monitoring guidelines and default settings
6
SFP monitoring guidelines and default settings
The SFP class groups areas that monitor the physical aspects of SFPs. An SFP class alarm alerts
you to an SFP malfunction fault. SFP performance monitoring is not supported on VE_Ports or
VEX_Ports.
NOTE
SFPs connected to GbE ports are not monitored.
SFP class areas
Table 7 lists Product Name areas in the SFP class and describes each area. Configure the SFP
class using the thConfig command.
NOTE
SFPs connected to GbE ports are not monitored.
SFP monitoring setting guidelines
Use the SFP default settings. The default alarm configuration (log all alarms only to the error log) is
sufficient. It is recommended that you do not allow alerts to go out as SNMP traps. If other Port
class issues are reported, review the error log for any supporting data for SFP issues.
TABLE 7 SFP class areas
Area Description
Temperature Measures the physical temperature of the SFP, in degrees Celsius. A high temperature
indicates that the SFP might be in danger of damage.
Receive power
(RXP)
Measures the amount of incoming laser, in µwatts, to help determine if the SFP is in good
working condition. If the counter often exceeds the threshold, the SFP is deteriorating.
Transmit power
(TXP)
Measures the amount of outgoing laser, in µwatts. Use this to determine the condition of the
SFP. If the counter often exceeds the threshold, the SFP is deteriorating.
Current Measures the amount of supplied current to the SFP transceiver. Current area events
indicate hardware failures.
Voltage Measures the amount of voltage supplied to the SFP. If this value exceeds the threshold, the
SFP is deteriorating.
State Changes Indicates whether the state of the SFP is normal or faulty, on or off. A faulty or off state
means that you must reinsert, turn on, or replace the SFP. Fabric Watch monitors only the
digital diagnostic SFP.
Note: SFPs connected to GbE ports are not monitored.