Port class guidelines and default settings
7
Port class guidelines and default settings
There are different recommendations and default settings for the physical port, the E_Port, and the
FOP_Port and FCU_Port. Please refer to the following sections and plan carefully before you begin
configuring the port.
“Physical port setting guidelines”
“E_Port subclass setting guidelines”
“FOP_Port and FCU_Port subclass setting guidelines”
NOTE
E_Ports and VE_Ports are not supported in Access Gateway mode.
Physical port setting guidelines
For the physical port, use the default settings listed in Table 15 for all areas and alarms except for
Invalid Transmission Words and Invalid CRC Count. For Invalid Transmission Words and Invalid CRC
Count, the alarms should be set at two points: a low boundary and a high boundary, with the goal to
alarm as the number of invalid words per minute rises above the low boundary and again as it rises
above the high boundary. it is recommended that you set the high boundary at 25 and set the
alarms to alert the error log any time this high boundary is exceeded.
Port class default settings
Table 15 provides default settings for areas in the Port class.
TABLE 15 Port class default settings
Area Description Default threshold
settings
Default alarm settings Threshold state
Class 3 Discards Class 3 discards
frames due to
timeout or
destination
unreachable.
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Invalid CRC Count Monitors the
number of CRC
errors
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Invalid Transmission
Words
Monitors the
number of invalid
words transmitted
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Link Failure Count Monitors the
number of link
failures
Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range