Fabric Watch Administrator's Guide v6.4.0 (53-1001770-01, June 2010)

60 Fabric Watch Administrator’s Guide
53-1001770-01
Port class guidelines and default settings
7
Loss of Signal Count Monitors the
number of signal
loss errors
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Loss of
Synchronization
Count
Monitors the
number of loss of
synchronization
errors
Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Link Reset Monitors the
number of link
resets sent by a
given port (LR-Out)
and received on a
given port (LR-In).
Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Primitive Sequence
Protocol Error
Monitors the
number of primitive
sequence errors
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Receive (Rx)
Performance
Monitors receive
rate, by percentage
Unit: Percentage (%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
State Changes Monitors state
changes
Unit: Changes
Time Base: minute
Low:0
High: 50
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Transmit (Tx)
Performance
Monitors
transmission rate, by
percentage
Unit: Percentage (%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
TABLE 15 Port class default settings (Continued)
Area Description Default threshold
settings
Default alarm settings Threshold state