Fabric Watch Administrator's Guide v6.4.0 (53-1001770-01, June 2010)

78 Fabric Watch Administrator’s Guide
53-1001770-01
Recommended port configuration settings
7
Recommended port configuration settings
Table 21 lists the recommended settings for physical port, E_Port, FOP_Port, and FCU_Port for both
the host device and the storage device.
TABLE 21 Recommended configuration for the Port class
E=Error_Log, S=SNMP_Trap,
P=Port_LOG_LOCK,
M=EMAIL_ALERT, pf=Port Fence
Trait Configuration
Class
Area
Default
Custom
Unit
Time Base
Low Thresh
High Thresh
Buffer
Default
Custom
Changed
Below
Above
In-between
Notes
Port Link Loss X Errors Minute 0 500 50 X
Sync Loss X Errors Minute 0 500 50 X
Signal LossX Errors Minute050X
Protocol ErrorX Errors Minute050X
Invalid Words X Errors Minute 0 25 0 X E
Invalid CRCs X Errors Minute 0 5 0 X E
RX
Performance
XPercentageMinute01000X
TX Performance X Percentage Minute 0 100 0 X
State Changes X Changes Minute 0 50 0 X
Link Reset X Errors Minute 0 500 50 X
C3 Discard X Errors Minute050X
E_Port Link Loss X Errors Minute 0 0 0 X E,S
Sync Loss X Errors Minute 0 45 0 X E,S
Signal Loss X Errors Minute 0 45 0 X E,S
Protocol ErrorX Errors Minute050X
Invalid Words X Errors Minute 0 40 0 X E,S,F pf
Invalid CRCs X Errors Minute 0 20 0 X E,S,F pf
RX
Performance
XPercentage Minute0 75 0 X E E
TX Performance X Percentage Minute 0 75 0 X E E
State Changes
(E/VE_Port)
X Changes Minute 0 50 0 X
Link Reset X Errors Minute 0 500 50 X
Utilization
(VE_Port)
XPercentageMinute01000X
Packet Loss
(VE_Port)
XErrors Minute0100X