FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Edge Switch 2/32 Installation Guide (AA-RSTZE-TE/958-000290-003, March 2005)

Technical specifications104
Ports Port Names NULL strings
Port Blocked States Unblocked
FAN Enabled
LIN Alerts (see page 49) Enabled
Ports enabled 8
Switch addressing IP Address 10.1.1.10
Subnet Mask 255.0.0.0
Gateway Address 0.0.0.0
MAC Address PROM value
Operating mode Must select one of two modes:
Open Fabric 1.0 or McData
Fabric 1.0. HP recommends
using the Open Fabric 1.0
mode. McData Fabric 1.0 must
be homogeneous.
Open Fabric 1.0 mode
Operating
parameters
Preferred Domain ID 1
R_A_TOV 10 seconds (100 tenths)
E_D_TOV 2 seconds (20 tenths)
Switch Priority Default
Switch Speed 2 Gb/sec
Rerouting Delay Enabled
SNMP SNMP Communities public” — 5 NULL strings
SNMP Write Authorizations Read only per community
Trap Recipient IP Addressees 0 for each
UDP Port 162
SNMP Authorization Trap State disabled
Management
appliance
Active Equal Saved State Disabled
Remote Offline Control State Disabled
Table 5 Switch factory-default values for reset configuration option (continued)
Configuration Description Default