FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Edge Switch 2/32 Installation Guide (AA-RSTZE-TE/958-000290-003, March 2005)
Technical specifications106
Power requirements
Table 8 lists Edge Switch 2/32 power requirements.
Operating tolerances
Table 9 lists heating and cooling specifications, shock and vibration tolerance, acoustical noise,
and inclination.
Maximum wet-bulb
temperature
84° F (29° C) 84°F (29°C) 81°F (27°C)
Altitude 40,000 ft
(12,192 m)
40,000 ft
(12,192 m)
10,000 ft
(3,048 m)
Table 7 Environmental specifications (continued)
Specification Shipping Storage Operating
Table 8 Power requirements
Specification Value
Input voltage 100 to 240 VAC
Input frequency 47 to 63 Hz
Table 9 Operating tolerances
Specification Value
Heat dissipation 836 BTU/hr (32 ports)
Cooling airflow
clearances
Right and left sides: No clearance required
Front and rear: 7.6 cm (3.0 in)
Top and bottom: No clearance required
Shock and vibration
tolerance
60 Gs for 10 milliseconds without nonrecoverable errors
Acoustical noise 6.6 Bels
Inclination 10° maximum