FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Edge Switch 2/32 Installation Guide (AA-RSTZE-TE/958-000290-003, March 2005)
Edge Switch 2/32 installation guide 37
3. Select Element Manager from the pop-up menu. When the Element Manager application opens,
the last view (tab) accessed by a user opens by default. The example in Figure 16 shows the
Hardware View.
Figure 16 Switch Hardware View page
4. Inspect switch status at the Hardware View page and perform one of the following steps:
a. If the switch displays the Operational state (no FRU alert symbols and a green circle at the
alert panel), go to ”Set Switch date and time” on page 38.
b. If the switch displays the Degraded state or a switch failure is indicated (FRU alert symbols
and a yellow triangle or red diamond at the alert panel), refer to the HP StorageWorks Edge
Switch 2/32 service manual to isolate the problem.