FW 08.01.00/HAFM SW 08.06.xx or later HP StorageWorks Edge Switch 2/32 Installation Guide (AA-RSTZF-TE, November 2005)

Edge Switch 2/32 installation guide 57
The Configure Ports dialog box is displayed (Figure 25).
a. Select a blank Name box and enter a descriptive port name of 24 or fewer alphanumeric
characters. Use a name that reflects the device connected to the port.
b. Select or clear the Blocked check box to block or unblock a port.
A check mark in the box indicates the port is blocked. Blocking the port prevents the
attached device from communicating with the Edge Switch. A blocked port continuously
transmits the offline sequence (OLS).
Figure 25 Configure Ports dialog box
NOTE: The fourth column in the Configure Ports dialog box is labled 10–100 km or RX BB
Credit, depending on your configuration. If an Edge Switch supports BB credits by port, an
RX BB Credit column is displayed.
c. Perform one of the following actions, depending on which column you have displayed in
your Configure Ports dialog box.
•Click 10–100 km to enable extended distance buffering for a port.
A check mark in the box indicates extended distance operation up to 100 kilometers
(through repeaters) is enabled.
Enter a value in the RX BB Credit column to set minimum and maximum allowable port BB
credit values. These values vary by Director.
If an invalid value is entered, an Invalid RX BB Credit error message is displayed. The
BB Credit value is validated as entered.
Click Activate and a RX-BB Credit Confirmation box is displayed. In addition to the maximum
BB credit limit per port, the total BB credits allocated to all ports cannot exceed the buffer
pool size.