FW 08.01.00/HAFM SW 08.06.xx or later HP StorageWorks Edge Switch 2/32 Installation Guide (AA-RSTZF-TE, November 2005)
Edge Switch 2/32 installation guide 59
Configuring SNMP trap message recipients
Perform this procedure to configure community names, write authorizations, and network addresses
for up to 12 SNMP trap message recipients per HAFM appliance or up to 6 SNMP trap message
recipients per Edge Switch. A trap recipient is a management workstation that receives notification
(through SNMP) if an Edge Switch event occurs.
1. At the Hardware view for the selected Edge Switch, select Configure > SNMP Agent.
The Configure SNMP Agent dialog box is displayed (Figure 26).
Figure 26 Configure SNMP Agent dialog box
a. For each trap recipient to be configured, enter a community name of 64 or fewer
alphanumeric characters in the associated Community Name box.
The community name is incorporated in SNMP trap messages to ensure against
unauthorized viewing or use.
b. Select or clear the Write Authorization check box to enable or disable write authorization for
the trap recipient (default is disabled).
A check mark in the box indicates write authorization is enabled. When the feature is
enabled, a management workstation user can change the HAFM appliance’s
sysContact, sysName, and sysLocation SNMP variables.
c. Enter the IP address or DNS host name of the trap recipient (SNMP management
workstation) in the associated Trap Recipient box. Use 32 or fewer alphanumeric characters.
HP recommends using the IP address.
d. Enter a decimal port number in the UDP Port Number box to override the default user
datagram protocol (UDP) port number for trap recipients (default is 162).
2. To enable transmission of trap messages to configured SNMP management workstations, select
Enable Authorization Traps.
3. Click Activate to save the information and close the dialog box.
Configuring, enabling, and testing e-mail notification
Perform this procedure to configure, enable, and test e-mail and simple mail transfer protocol
(SMTP) addresses to receive notification of Edge Switch (and other product) events. Configure and
test procedures are performed at the HAFM appliance. E-mail notification is enabled for each Edge
Switch at the HAFM application.