FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/32 Installation Guide (AA-RSTZD-TE, July 2004)
Using the Embedded Web Server
108 Edge Switch 2/32 Installation Guide
Configure Switch and Fabric Parameters
Perform this procedure to configure the following switch and fabric operating
parameters: Buffer-to-Buffer Credit (BB_Credit), Error Detect Time Out Value
(E_D_TOV), and Resource Allocation Time Out Value (R_A_TOV), preferred
domain ID and switch priority.
Configure Switch Parameters
The switch must be set offline to configure operating parameters. To configure the
parameters:
1. Set the switch offline as follows:
a. At the View window, select Operations at the left side of the panel. The
Operations panel opens with the Switch Beacon page displayed.
b. At the Current State window, click Set Offline. The message Your
operations changes have been successfully
activated displays.
2. At the View window, select Configure at the left side of the panel. The
Configure panel opens with the Ports page displayed.
3. At the Configure panel, click the Switch tab, then select Parameters. The
Switch page displays with Switch Parameters shown (Figure 45).
Figure 45: Switch page—Parameters tab