FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/32 Installation Guide (AA-RSTZD-TE, July 2004)
Using the Embedded Web Server
111Edge Switch 2/32 Installation Guide
All fabric-attached switches must be set to the same R_A_TOV. If the
value is not compatible, the E_Port connection to the switch segments and
the switch cannot communicate with the fabric. In addition, the
R_A_TOV must be greater than the E_D_TOV.
c. At the E_D_TOV field, enter a value from 2 through 600 tenths of a
second (0.2 through 60 seconds). The default is 20 tenths of a second
(2 seconds).
All fabric-attached switches must be set to the same E_D_TOV. If the
value is not compatible, the E_Port connection to the switch segments and
the switch cannot communicate with the fabric. In addition, the
E_D_TOV must be less than the R_A_TOV.
d. The switch priority value designates the fabric’s principal switch. The
principal switch controls the allocation and distribution of domain IDs for
all fabric directors and switches (including itself). At the Switch Priority
field, select Principal, Never Principal, or Default (the default setting is
Default).
e. Select the Interop mode:
— McData Fabric 1.0. (default). Select this mode if the fabric contains
only M-Series switches and switches that are operating in McData
Fabric 1.0 mode.
— Open Fabric 1.0. Select this mode if the fabric contains HP directors
and switches, as well as other open-fabric compliant switches. Select
this mode for managing heterogeneous fabrics.
5. Click Activate to save the information. The message Your changes to
the operating parameters configuration have been
successfully activated displays.
6. Set the switch online:
a. At the View window, select Operations at the left side of the panel. The
Operations panel opens with the Switch Beacon page displayed.
b. At the Operations panel, click the Online State tab, then click Set
Online. The message Your operations changes have been
successfully activated displays.