FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/32 Service Manual (AA-RS2GD-TE, July 2004)

Diagnostics
105Edge Switch 2/24 Service Manual
35
Inspect the fiber-optic jumper cable attached to the port and ensure the cable is not
bent and connectors are not damaged. If the cable is bent or connectors are
damaged:
1. Notify the customer the port will be blocked. Ensure the customer’s system
administrator quiesces Fibre Channel frame traffic through the port and sets
the attached device offline.
2. Block the port. Refer to “Clean Fiber-Optic Components” on page 153.
3. Remove and replace the fiber-optic jumper cable.
4. Unblock the port. Refer to “Clean Fiber-Optic Components” on page 153.
Was a corrective action performed?
YES NO
Go to step 37.
36
Monitor port operation for approximately five minutes.
Did the link incident recur?
YES NO
The Fibre Channel link and switch appear operational. Exit MAP.
37
Clean fiber-optic connectors on the jumper cable.
1. Notify the customer the port will be blocked. Ensure the customer’s system
administrator quiesces Fibre Channel frame traffic through the port and sets
the attached device offline.
2. Block the port. Refer to “Clean Fiber-Optic Components” on page 153.
3. Disconnect both ends of the fiber-optic cable.
4. Clean the fiber-optic connectors. Refer to “IML, IPL, or Reset the Switch” on
page 156.
5. Reconnect the fiber-optic cable.
6. Unblock the port. Refer to “Clean Fiber-Optic Components” on page 153.
7. Monitor port operation for approximately five minutes.