Repair Information
135Edge Switch 2/24 Service Manual
Obtaining Port Diagnostic Information
Fibre channel port diagnostics are performed at the switch and Element Manager
application. These diagnostics include:
Inspecting port LEDs at the switch front panel or emulated port LEDs at the
HAFM Hardware View.
Inspecting parameters at the HAFM appliance (Edge Switch 2/32 Element
Manager application).
Inspecting parameters at the EWS interface (refer to the HP StorageWorks
Embedded Web Server User Guide for more information).
Performing channel wrap tests. The tests apply only to a switch configured for
FICON management style.
Port LEDs
To obtain port operational information, inspect port LEDs at the switch front
panel or emulated port LEDs at the HAFM Hardware View.
Amber and green LEDs adjacent to each port indicate operational status as
follows:
The green LED illuminates (or blinks if there is active traffic) and the amber
LED extinguishes to indicate normal port operation.
The amber LED illuminates and the green LED extinguishes to indicate a port
failure.
Both LEDs extinguish to indicate a port is operational but not communicating
(no SFP installed, no cable attached, loss of light, port blocked, or link
recovery in process).
The amber LED flashes and the green LED illuminates (or blinks if there is
active traffic) to indicate beaconing is set for the port.
The amber LED flashes and the green LED extinguishes to indicate a port is
running online diagnostics, or beaconing is set and the port is not communicating
(no SFP installed, no cable attached, loss of light, port blocked, or link recovery in
process).