FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/32 Service Manual (AA-RS2GD-TE, July 2004)

Repair Information
137Edge Switch 2/24 Service Manual
#—The switch port number (0 through 139 inclusive).
Addr—The switch logical port address in hexadecimal format (FICON
management style only).
Name—The port name configured through the Configure Ports dialog box.
Block Config—The port status (Blocked or Unblocked).
State—The operating state of the port. Valid states are:
Online, Offline, or Testing
Beaconing
Invalid Attachment
Link Incident or Link Reset
No Light, Not Operational, or Port Failure
Segmented E_Port
Type—The type of port. Valid port types are a generic port (G_Port) not
connected to a Fibre Channel device, director, or switch (therefore light is not
transmitted); a fabric port (F_Port) connected to a device; or an expansion
port (E_Port) connected to a director or switch to form an interswitch link
(ISL).
Operating Speed—The operating speed of the port (Not Established, 1, or 2
Gb/sec.).
Alert—If Link Incident (LIN) alerts are configured for the port through the
Configure Ports dialog box, a yellow triangle displays in the column when a
link incident occurs. A yellow triangle also displays if beaconing is enabled
for the port. A red and yellow diamond displays if the port fails.
Double-click anywhere in a row for an installed port to open the Port Properties
dialog box.
Right-click anywhere in a row for an installed port to open a menu to:
Open the Port Properties, Node Properties, or Port Technology dialog boxes.
Block or unblock the port.
Enable or disable port beaconing.
Perform port diagnostics.
Enable or disable port channel wrapping. This menu option displays only
when the switch is configured for FICON management style.