FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/32 Service Manual (AA-RS2GD-TE, July 2004)
FRU Removal and Replacement
185Edge Switch 2/24 Service Manual
RRP: Cooling Fan
Use the following procedures to remove or replace a cooling fan FRU from the
rear of the switch. No tools are required.
Removal
To remove a cooling fan:
1. Identify the defective cooling fan from the illuminated amber LED on the fan
or failure information at the HAFM appliance Hardware View.
2. Loosen the fan retaining screw in the upper right corner of the fan. The
retaining screw is captive and will remain in the fan assembly.
3. Grasp the fan handle and pull the fan FRU out of the chassis.
Replacement
To replace a cooling fan:
1. Remove the replacement cooling fan FRU from its shipping container.
2. Inspect the rear of the fan for bent or broken connector pins. If any pins are
damaged, obtain a new fan.
3. Position the fan FRU with its retaining screw at the upper right corner (the fan
cannot be inserted in any other position).
4. Push the fan FRU into the chassis to engage the connector pins. Ensure that
the fan FRU faceplate is flush with the chassis.
5. Engage the screw threads and lightly tighten the screw. Over-tightening the
screw may damage the FRU or chassis.
6. Inspect the fan FRU to ensure that the amber LED is extinguished. If the
amber LED is illuminated, go to “MAP 0000: Start MAP” on page 29 to
isolate the problem.
7. At the HAFM appliance Hardware View, click Event Log from the Logs
icon. The Event Log window displays. Ensure one of the following event
codes displays in the log:
310 to 315 — Nth cooling fan has recovered, where N is first to fourth (fan).