FRU Removal and Replacement
187Edge Switch 2/24 Service Manual
5. Raise the black plastic latch lever to the vertical position.
The power supply cams into its seated position in the chassis.
6. Rotate the power lockout lever to the left to cover the plastic lever and expose
the AC connector.
7. Verifying that the power switch is off, connect the AC power cord to the
power supply and to a facility power source.
8. Turn on the power switch.
9. Inspect the power supply to ensure that the green LED is illuminated. If the
green LED is extinguished, go to“MAP 0000: Start MAP” on page 29 to
isolate the problem.
10. At the HAFM appliance Hardware View, select Event Log from the Logs
icon. The Event Log displays. Ensure the following event codes display in the
log:
■ 203 — Power supply AC voltage recovery.
■ 204 — Power supply DC voltage recovery.
11. At the HAFM appliance Hardware View, observe the power supply graphic
and ensure no alert symbols display that indicate a failure (yellow triangle or
red diamond). If a problem is indicated, go to “MAP 0000: Start MAP” on
page 29 to isolate the problem.
12. Perform the data collection procedure (refer to
“Collecting Maintenance Data” on
page 151
).
13. Clear the switch system error (ERR) LED:
a. At the HAFM appliance Hardware View, right-click the front panel bezel
graphic (away from a FRU) to open a pop-up menu.
Click the Clear System Error Light menu selection.