FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/32 Service Manual (AA-RS2GD-TE, July 2004)

Messages
212 Edge Switch 2/24 Service Manual
Cannot change Port
Type while Management
Style is FICON without
SANtegrity feature.
Please contact your sales
representative.
Firmware is below the
required level and you
attempted to change a
port type in the
Configure Ports dialog
box while FICON
management style, but
the optional SANtegrity
Binding feature is not
installed.
Informational message. If
the firmware is below the
required level, install
SANtegrity Binding before
changing port types in the
Configure Ports dialog box
while in FICON
management style.
Cannot disable Switch
Binding while Enterprise
Fabric Mode is active
and the switch is Online.
User attempted to
disable switch binding
through the Switch
Binding Change State
dialog box, but
Enterprise Fabric Mode
is enabled.
You must either disable
Enterprise Fabric Mode
using the Enterprise Fabric
Mode dialog box in the
HAFM
application or set
the switch offline before
you can disable Switch
Binding.
Cannot disable Insistent
Domain ID while Fabric
Binding is active.
User attempted to
disable the Insistent
Domain ID parameter
through the Configure
Switch Parameters
dialog box, but Fabric
Binding is enabled.
Disable Fabric Binding
through the Fabric Binding
dialog box before
disabling these parameters.
Cannot enable
beaconing on a failed
FRU.
Occurs when selecting
Enable Beaconing
option for a failed FRU.
Replace FRU and enable
beaconing again or enable
beaconing on operating
FRU.
Cannot enable
beaconing while the
system error light is on.
Beaconing cannot be
enabled while the system
error light is on.
Select Clear System Error
Light from Product menu to
clear error light, then
enable beaconing.
Table 25:
Edge Switch 2/32 Element Manager Messages (Continued)
Message Description Action