FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/32 Service Manual (AA-RS2GD-TE, July 2004)
Messages
225Edge Switch 2/24 Service Manual
Port diagnostics cannot
be performed on an
inactive port.
This displays when port
diagnostics is run on a
port in an inactive state.
Run the diagnostics on an
active port.
Port speeds cannot be
configured at a higher
rate than the
director/switch speed.
This displays when you
configure a port to 2
GB/sec and the switch
speed is set to 1 Gb/sec.
Set the port speed to 1
Gb/sec in the Configure
Operating Parameters
dialog box.
Element Manager error
<number>.
The switch Element
Manager encountered
an internal error and
cannot continue.
Report the problem to
support personnel.
Element Manager
instance is currently
open.
An Element Manager
window is currently
open.
N/A. Informational
message.
R_A_TOV must be
greater than E_D_TOV.
R_A_TOV must be
greater than E_D_TOV.
Change one of the values
so that R_A_TOV is greater
than E_D_TOV.
Resource is unavailable. The specified operation
cannot be performed
because the product is
unavailable.
Verify that the HAFM
appliance-to-product link is
up. If the link is up, the
HAFM appliance may be
busy. Try the operation
again later.
SANtegrity Feature not
installed. Please contact
your sales
representative.
The user selected Switch
Binding from the
Configure menu, but the
optional SANtegrity
Binding feature is not
installed.
Install the SANtegrity key
through the Configure
Feature Key dialog box
before using Switch
Binding features.
Send firmware failed. Send firmware
operation has failed.
Retry the operation. If the
condition persists, contact
support personnel.
SNMP trap address not
defined.
An SNMP trap address
must be defined if a
community name is
defined.
Define an SNMP address.
Table 25:
Edge Switch 2/32 Element Manager Messages (Continued)
Message Description Action