FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/32 Service Manual (AA-RS2GD-TE, July 2004)
Event Codes
231Edge Switch 2/24 Service Manual
System Events (000 through 199)
Table 26: Event Code 001
Message: System power-down.
Severity: Informational.
Explanation: The switch was powered off or disconnected from the facility AC power source. The
event code is distributed the next time the switch powers on, but the date and time
of the code reflect the power-off time.
Action: No action required.
Event Data: No supplementary data included with the event.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Table 27: Event Code 011
Message: Login Server database invalid.
Severity: Minor.
Explanation: Following an initial machine load (IML) or firmware download, the Login Server
database failed its cyclic redundancy check (CRC) validation. All Fabric Services
databases are initialized to an empty state, resulting in an implicit Fabric logout of
all attached devices.
Action: Perform the data collection procedure and return the backup disk to
Hewlett-Packard support personnel.
Event Data: No supplementary data included with this event.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔