Event Codes
276 Edge Switch 2/24 Service Manual
Table 92: Event Code 584
Message: Not operational primitive sequence received.
Severity: Major.
Explanation: An attached OSI server received a not-operational primitive sequence (NOS).
Action: An LIR is generated and sent to the attached server using the reporting procedure
defined in T11/99-017v0 (OSI). If fault isolation at the server does not detect a
failure, the problem may be due to a port failure. Go toMAP 0000: Start MAP” on
page 29 to perform fault isolation.
Event Data: Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Table 93: Event Code 585
Message: Primitive sequence timeout.
Severity: Major.
Explanation: An attached OSI server recognized either a link reset (LR) protocol timeout or a
timeout while waiting for the appropriate response (while in a NOS receive state
and after NOS was not longer recognized).
Action: An LIR is generated and sent to the attached server using the reporting procedure
defined in T11/99-017v0 (OSI). If fault isolation at the server does not detect a
failure, the problem may be due to a port failure. Go toMAP 0000: Start MAP” on
page 29 to perform fault isolation.
Event Data: Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔