FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/32 Service Manual (AA-RS2GD-TE, July 2004)
Event Codes
278 Edge Switch 2/24 Service Manual
SBAR Events (600 through 699)
In the Edge Switch 2/32, the SBAR is not a separate assembly, therefore not a
FRU. It is an integral part of the switch’s main circuit board. SBAR failure
requires replacement of the entire switch.
Table 95: Event Code 602
Message: SBAR module anomaly detected.
Severity: Informational.
Explanation: Indicates that the control processor has detected a deviation in the normal operating
mode or operating status of the indicated SBAR module.
Action: No action required. There will be an additional event generated (604) if this event
results in an SBAR logic failure.
Event Data: Byte 0 = Slot position.
Byte 1 = Anomaly reason code (See following chart).
Bytes 4–7 = Elapsed millisecond tick count.
Bytes 8–9 = High Availability error callout #1.
Bytes 10–11 = High Availability error callout #2.
Byte 12 = Detecting port.
Byte 13 = Connected port.
Byte 14 = Participating SBAR.
Bytes 16–17 = High Availability error callout #3.
Bytes 18–19 = High Availability error callout #4.
Distribution: Switch HAFM Appliance Host
Non-
volatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔