FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/32 Service Manual (AA-RS2GD-TE, July 2004)

Event Codes
281Edge Switch 2/24 Service Manual
Thermal Events (800 through 899)
Table 98: Event Code 805
Message: High-temperature warning (SBAR module thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with the SBAR module has detected that the “warm”
temperature threshold level has been surpassed.
Action: Perform the data collection procedure for this switch using HAFM, Save the data file
to the HAFM backup drive, and return the backup disk to HP support personnel for
analysis. Perform a system power-on reset. If the problem persists, replace the
switch.
Event Data: No supplementary data included with this event.
Distribution: Switch HAFM Appliance Host
EWS
Event Log
System
Error
Indicator
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Table 99: Event Code 806
Message: Critically hot temperature warning (SBAR module thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with the SBAR module has detected that the “hot”
temperature threshold level has been surpassed.
Action: Perform the data collection procedure for this switch using HAFM, Save the data file
to the HAFM backup drive, and return the backup disk to HP support personnel for
analysis. Perform a system power-on reset. If the problem persists, replace the
switch.
Event Data: No supplementary data included with this event.
Distribution: Switch HAFM Appliance Host
EWS
Event Log
System
Error
Indicator
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔