FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/32 Service Manual (AA-RS2GD-TE, July 2004)
Event Codes
282 Edge Switch 2/24 Service Manual
Table 100: Event Code 807
Message: SBAR module shutdown due to thermal violation.
Severity: Major.
Explanation: The SBAR Module has been marked failed and power has been removed from the
module due to excessive heat. This event follows an indication that the SBAR module
“hot” threshold level has been surpassed (event 806).
Action: Perform the data collection procedure for this switch using HAFM, Save the data file
to the HAFM backup drive, and return the backup disk to HP support personnel for
analysis. Perform a system power-on reset. If the problem persists, replace the
switch.
Event Data: No supplementary data included with this event.
Distribution: Switch HAFM Appliance Host
EWS
Event Log
System
Error
Indicator
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Table 101: Event Code 810
Message: High temperature warning (CTP card thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with a CTP card indicates the warm temperature
threshold was reached or exceeded.
Action: Replace the failed switch. Perform the data collection procedure and return the
backup disk and faulty switch to Hewlett-Packard support personnel.
Event Data: No supplementary data included with this event.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
Indicator
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔