FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/32 Service Manual (AA-RS2GD-TE, July 2004)
Diagnostics
32 Edge Switch 2/24 Service Manual
↓ A FRU failure or link incident is indicated. Go to step 18 to obtain
event codes that identify the failure. Exit MAP.
9
A switch-to-PC Internet link problem (Internet too busy or IP address typed
incorrectly) is indicated.
1. Wait approximately five minutes, then attempt to login to the switch again.
2. At the Netsite field (Netscape Navigator) or Address field (Internet
Explorer), type http://xxx.xxx.xxx.xxx, where
xxx.xxx.xxx.xxx is the IP address of the switch (obtained in step 1). The
Username and Password Required dialog box appears (Figure 4).
3. Type the user name and password obtained in step 1, and click OK. If the
View panel does not display, wait another five minutes and perform this step
again.
Does the EWS interface appear operational with the View panel displayed?
YES NO
↓ Perform switch fault isolation at the HAFM appliance. Go to step 20.
10
At the View panel, inspect the Status field.
Does the switch status indicate Operational?
NO YES
↓ The switch appears operational. Exit MAP.
11
Inspect Fibre Channel port operational states.
1. At the View panel, click the Port Properties tab. The View panel (Port
Properties tab) displays with port 0 highlighted (Figure 6).