FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/32 Service Manual (AA-RS2GD-TE, July 2004)

Diagnostics
84 Edge Switch 2/24 Service Manual
MAP 0000: Start MAP” on page 29This MAP describes fault isolation for the
CTP (which is not an FRU) and fan FRUs. Failure indicators include:
The amber LED on a fan illuminates.
The amber emulated LED on a fan graphic at the Hardware View
illuminates.
A blinking red and yellow diamond (failed FRU indicator) displays at the
Hardware View.
An event code recorded at the switch Event Log or the Embedded Web
Server Event Log.
A Failed or Not Installed message associated with a fan at the
Embedded Web Server interface.
1
Was an event code 300, 301, 302, 303, 304, 305, 306, 307; or 604, 605, 607; or
800, 801, 802, 805, 806, 807, 810, 811, 812, or 850 observed at the switch Event
Log (HAFM appliance) or at the Embedded Web Server Event Log?
YES NO
Go to step 3.
2
Table 8 lists event codes, brief explanations of the codes, and associated steps that
describe fault isolation procedures.
Table 8: MAP 500: Event Codes
Event
Code
Explanation Action
300 First cooling fan failed. Go to step 8.
301 Second cooling fan failed. Go to step 8.
302 Third cooling fan failed. Go to step 8.
303 Fourth cooling fan failed. Go to step 8.
604 SBAR failure. Go to step 14.
605 SBAR revision not supported. Go to step 12.
800 High-temperature warning (port module sensor). Go to step 8.
801 Critically hot temperature warning (port module
thermal sensor).
Go to step 8.