FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/32 Service Manual (AA-RS2GD-TE, July 2004)
Diagnostics
85Edge Switch 2/24 Service Manual
3
Is remote fault isolation being performed at the switch or HAFM appliance?
YES NO
↓ Remote fault isolation is being performed through the Embedded Web
Server interface. Go to step 6.
4
Does a blinking red and yellow diamond (failed FRU indicator) overlay a fan
(cooling fan assembly) graphic at the Hardware View?
NO YES
↓ Go to step 8.
5
Does inspection of a fan indicate a failure? Indicators include:
■ The amber LED at the upper left corner of a fan illuminates.
■ The fan is not rotating.
NO YES
↓ Go to step 8.
802 Port module shutdown due to thermal violations. Go to step 8.
805 High-temperature warning (SBAR thermal
sensor).
Go to step 8.
806 Critically hot temperature warning (SBAR thermal
sensor).
Go to step 8.
807 SBAR shutdown due to thermal violation. Go to step 8.
810 High temperature warning (CTP thermal sensor). Go to step 8.
811 Critically hot temperature warning (CTP thermal
sensor).
Go to step 8.
812 CTP shutdown due to thermal violation. Go to step 8.
850 System shutdown due to CTP thermal violations. Go to step 8.
Table 8: MAP 500: Event Codes
Event
Code
Explanation Action