FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/32 Service Manual (AA-RS2GD-TE, July 2004)

Diagnostics
86 Edge Switch 2/24 Service Manual
The switch appears operational. Exit MAP.
6
Does the Embedded Web Server interface appear operational?
YES NO
Analysis for an Ethernet link, AC power distribution, or CTP failure is not
described in this MAP. Go to “MAP 0000: Start MAP” on page 29. If this
is the second time at this step, contact the next level of support.
7
Inspect the fan operational states at the Embedded Web Server interface.
1. At the View panel, click the FRU Properties tab. The View panel (FRU
Properties tab) displays.
2. Inspect the Status fields for Fan 0 through Fan 3.
Does the Status field display a Failed message for any fan?
YES NO
The switch appears operational. Exit MAP.
8
A fan failed or is improperly installed.
1. Partially remove the fan from the chassis.
2. Reseat the fan in the chassis.
Does the fan appear to function?
NO YES
The switch appears operational. Exit MAP.
9
A fan failed and must be removed and replaced (“RRP: Cooling Fan” on
page 185).
Does the fan appear to function?
NO YES
The switch appears operational.