HP StorageWorks Edge Switch 2/32 Flexport Upgrade Instructions (AA-RS33G-TE/958-00291-005, January 2006)

Figure 2 Maintenance Feature Installation tab
7. Enter the feature key in the Feature Key box, and then click Update.
Aconrm
ation page contains a warning that this action will override the current set of features on
the switch.
8. Click OK to acti vate the new feature key.
The swit
ch performs an IPL when the key is activated and the feature key is installed.
NOTE:
When you
select OK, all current features are replaced with new features.
9. Back up the conguration data when you are nished conguring the switch.
Installing a feature key using HAFM
After obtaining the feature key, install the feature using HAFM as follows:
1. Log in to HAFM and access the H ardware View.
2. If your rmware is 04.01.02 or later, proceed to step 3.
or
If your rmware is earlier than 04.01.02, Select Maintenance > Set Ofine State to set the switch
ofine.
The Hardware View is displayed.
3. Select Congure > Features.
The Congure Feature Key dialog box is displayed (Figure 3).
14
Flexport upgrade instructions