HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
141Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Sun Solaris
Before beginning this procedure, make sure that your host is up to date with Solaris OS
patches. For supported revision levels, refer to the DRM Release Notes.
Install the HBAs
I You must install at least two HBAs in each host system. HBAs must be installed in pairs.
Record the HBA WWID for use later in this section. Refer to the Compaq StorageWorks
64-Bit PCI-to-Fibre Channel Host Bus Adapter User Guide for installation instructions. The
user guide is located at:
http://h18004.www1.hp.com/products/storageworks/techdoc/adapters/AA-RKPDB-TE.html.
Note: Do not attach your fiber connections to the HBAs until instructed to do so.
WARNING: PCI and Sbus HBAs cannot coexist on the same host.
Connect the Host to the SAN
Use your established cabling policy to connect the host to the Fibre Channel switch.
I 1. Use 50-micron, multimode fiber optic cable to connect one adapter of each pair to the top
Fibre Channel switch.
I 2. Use 50-micron, multimode fiber optic cable to connect the other adapter of each pair to the
bottom Fibre Channel switch.
Example: If there are four adapters in a server, the first and third adapters must be
connected to the top Fibre Channel switch; the second and fourth adapters must be
connected to the bottom Fibre Channel switch.
Install the Solaris Platform Kit
I 1. Install the Solaris platform kit following the instructions in the HP StorageWorks HSG80
ACS Solution Software Version 8.7 for Sun Solaris Installation and Configuration Guide.
Note that DRM requires the following deviations from the steps in this procedure:
Loop Mode. Disregard references to Loop Mode. Loop Mode is not supported in
DRM.
Fabric Mode. Ensure that the top HBA receives the world wide port number
(WWPN) of the corresponding top port 1 address of the controller, and that the bottom
HBA receives the WWPN of the corresponding bottom port 1 address of the
controller.
Note: Install the HBA drivers and the SWCC agent in this step. See the
HP StorageWorks HSG80
ACS Solution Software Version 8.7 for Sun Solaris Installation and Configuration Guide
for the list of
installed packages. Configure SWCC (as an option) in a later step.
I 2. Reboot the host using the reboot -- –r command.