HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Zoning in the Storage Area Network
205Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Note: Top_Fabric has already been created.
cfgAdd “Top_Fabric”, “Yellow Zone_Top; Brown Zone_Top”
This adds Yellow Zone_Top and Brown Zone_Top to a configuration file titled
“Top_Fabric,” which already contains Green Zone_Top, Blue Zone_Top,
Red Zone_Top, and their alias members. These are stored in flash memory for switches A
and Y.
3. Save the configuration:
cfgSave
4. Enable the new zone configuration:
cfgEnable “Top_Fabric”
Note: This configuration now becomes the effective (in use) configuration for both switches A
and Y.
5. To make this the active configuration after a restart or power-down, issue another
cfgSave command:
cfgSave
This ensures the effective configuration of the switches after a restart or power-down.
6. Verify that the Top_Fabric configuration is correct:
cfgShow
The system produces a display of the Top_Fabric configuration similar to the following:
Defined configuration:
cfg: Top_Fabric
Blue Zone_Top; Brown Zone_Top; Green Zone_Top;
Red Zone_Top; Yellow Zone Top
zone: Blue Zone_Top
. . . . . . . . . . . . . . . . Host 2_Y; Controller Y1_top
zone: Brown Zone_Top
Host 4_Y; Controller Y1_top
zone: Green Zone_Top
Host 1_A; Controller A1_top
zone: Red Zone_Top
Controller A2_top; Controller Y2_top
zone: Yellow Zone_Top
Host 3_A; Controller A1_top
alias: Controller A1_top
0,4
alias: Controller A2_top
0,6
alias: Controller Y1_top