HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Getting Started
49Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Table 5: Example of Wiring for First Server and First Storage Array at
Each Site
Note that additional servers and storage arrays will use other ports.
Changing SCSI Version from SCSI-2 to SCSI-3 on HSG80 Controllers
SCSI-3 is the preferred protocol for DRM. If your operating system supports SCSI-3, HP
recommends that you change from SCSI-2 to SCSI-3. You can use either the static or rolling
upgrade procedure for this change.
Static Upgrade Procedure
This procedure requires that you stop all I/O and unmount all devices to the HSG80
controllers.
1. Verify that your host’s operating system supports SCSI-3. You can determine this by
referring to the DRM Release Notes.
2. Check for LUN 0 and unused devices on the SCSI-2 HSG80 controllers by issuing the
following CLI command:
SHOW UNITS
You will see a display similar to Example Display 1.
Initiator Site Target Site
Host Port 1
Top Switch, Port 0 Host Port 1
Top Switch, Port 0
Host Port 2
Bottom Switch, Port 0 Host Port 2
Bottom Switch, Port 0
Controller A, Port 1
Top Switch, Port 2 Controller A, Port
1
Top Switch, Port 2
Controller A, Port 2
Top Switch, Port 4 Controller A, Port
2
Top Switch, Port 4
Controller B, Port 1
Bottom Switch, Port 2 Controller B, Port 1
Bottom Switch, Port 2
Controller B, Port 2
Bottom Switch, Port 4 Controller B, Port 2
Bottom Switch, Port 4
Between Initiator and Target Site
Top Switch, Port 6
External Fiber Link
Top Switch, Port 6
Bottom Switch, Port 6
External Fiber Link
Bottom switch, Port 6