HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
67Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Example Display 6
.
.
.
Mirrored Cache:
256 megabyte write cache, version 0012
Cache is GOOD
No unflushed data in cache
.
.
.
If the command is rejected, do not restart the controllers. Wait a few minutes and then try
again.
Note: It is not necessary to repeat this step on controller B.
T 21. Set the fabric topology for each port on both controllers by issuing the following CLI
commands:
Note: You are prompted to restart the controllers after each command, but you do not need to
restart the controllers until all topologies have been set.
SET THIS_CONTROLLER PORT_1_TOPOLOGY=FABRIC
SET THIS_CONTROLLER PORT_2_TOPOLOGY=FABRIC
SET OTHER_CONTROLLER PORT_1_TOPOLOGY=FABRIC
SET OTHER_CONTROLLER PORT_2_TOPOLOGY=FABRIC
T 22. Issue the CLI command:
SET LOG NOLOG
Note: You can ignore the error message ERROR B020:No Logdisk is Configured if
it appears.
T 23. Restart the controllers by issuing the following CLI commands in the order shown:
RESTART OTHER_CONTROLLER
RESTART THIS_CONTROLLER
Note: There may be a brief delay before control is returned.
T 24. After the controllers have restarted, verify that the topology is set correctly:
SHOW THIS_CONTROLLER
SHOW OTHER_CONTROLLER