HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
94 Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
T 2. Use the Secure Path Agent Configuration screen at the server to grant access to the client
at both the initiator and target sites. To do this:
a. From the NetWare server, toggle to the Secure Path NLM (NetWare Loadable
Module) screen.
b. At the Main menu, select 2) Client Administration, then select 2) Add a Client.
c. Type the fully qualified DNS name for the client, then press Enter.
d. Press Esc to return to the Main menu.
T 3. To set the password and allow client access via the Secure Path Agent Configuration,
execute the following procedure:
a. At the Main menu, select 1) Agent Administration, then select 1) Change
Password.
b. Type a password for client access and then retype the password for verification.
c. Press Esc to return to the Main menu.
Note: HP recommends that you set both the fully qualified and unqualified DNS names as
valid, authorized clients.
Install Secure Path Manager
T For installation instructions, refer to the current version of the HP StorageWorks Secure Path
for Novell NetWare Installation and Reference Guide.
Install SWCC (Optional)
T You may now install SWCC. For detailed information about SWCC, including installation,
refer to the Compaq StorageWorks Command Console Version 2.4 User Guide.
Connect the Host to the SAN
Use your established cabling policy to connect the host to the Fibre Channel switch.
T 1. Use 50-micron, multimode fiber optic cable to connect one adapter of each pair to the top
Fibre Channel switch.
T 2. Use 50-micron, multimode fiber optic cable to connect the other adapter of each pair to the
bottom Fibre Channel switch.
For example, if there are four adapters in a server, the first and third adapters must be
connected to the top Fibre Channel switch and the second and fourth adapters must be
connected to the bottom Fibre Channel switch.
T 3. Verify that the connection between the host and the switch has been made:
SHOW CONNECTIONS
You should see a display similar to that in Example Display 20.