HSG80 ACS Solution Software V8.6 for Windows NT and Windows 2000 Installation and Configuration Guide

5–2 HSG80 ACS Solution Software Version 8.6 for Windows NT and Windows 2000 Installation and
Configuration Guide
IMPORTANT: These configuration procedures assume that controllers and cache modules are
installed in a fully functional and populated enclosure and that the PCMCIA cards are installed.
To install a controller or cache module and the PCMCIA card, see the Compaq
StorageWorks HSG80 Array Controller ACS Version 8.6 Maintenance and Service Guide.
Establishing a Local Connection
A local connection is required to configure the controller until a command console LUN
(CCL) is established using the CLI. Communication with the controller can be through the
CLI or SWCC.
The maintenance port, shown in Figure 51, provides a way to connect a maintenance
terminal. The maintenance terminal can be an EIA-423 compatible terminal or a computer
running a terminal emulator program. The maintenance port accepts a standard RS-232
(RJ45) jack. The maintenance port cable shown in Figure 51 has a 9-pin connector
molded onto the end for a PC connection. If you need a terminal connection or a 25-pin
connection, you can order optional cabling.
Figure 5–1. Maintenance port connection
1 Maintenance Port Cable 2 Maintenance Port
CXO7181A