HSG80 ACS Solution Software V8.6 for Windows NT and Windows 2000 Installation and Configuration Guide

2–34 HSG80 ACS Solution Software Version 8.6 for Windows NT and Windows 2000 Installation and
Configuration Guide
Unit D101 is a 2-member striped mirrorset named S1. S1 consists of M1 and M2:
M1 is a 2-member mirrorset consisting of Disk10100 and Disk20100.
M2 is a 2-member mirrorset consisting of Disk30100 and Disk40100.
Unit D102 is a 2-member mirrorset named M3. M3 consists of Disk10200 and
Disk20200.
Unit D103 is a 2-member mirrorset named M4. M4 consists of Disk30200 and
Disk40200.
Unit D104 is 3-member stripeset named S2. S2 consists of Disk10300, Disk20300, and
Disk30300.
Unit D105 is a single (JBOD) disk named Disk40300.
Unit D106 is a 3-member RAID 3/5 storageset named R2. R2 consists of Disk10400,
Disk20400, and Disk30400.
Unit D107 is a single (JBOD) disk named Disk40400.
Unit D108 is a 4-member stripeset named S3. S3 consists of Disk10500, Disk20500,
Disk30500, and Disk40500.
Unit D1 is a 2-member striped mirrorset named S4. S4 consists of M5 and M6:
M5 is a 2-member mirrorset consisting of Disk10800 and Disk20800.
M6 is a 2-member mirrorset consisting of Disk30800 and Disk40800.
Unit D2 is a 4-member RAID 3/5 storageset named R3. R3 consists of Disk10900,
Disk20900, Disk30900, and Disk40900.
Unit D3 is a 4-member stripeset named S5. S5 consists of Disk11000, Disk21000,
Disk31000, and Disk41000.
Unit D4 is a 2-member mirrorset named M7. M7 consists of Disk11100 and
Disk21100.
Unit D5 is a 2-member stripeset named S6. S6 consists of Disk31100 and Disk41100.
Unit D6 is a 4-member RAID 3/5 storageset named R4. R4 consists of Disk11200,
Disk21200, Disk31200, and Disk41200.
Unit D7 is a 2-member mirrorset named M8. M8 consists of Disk11300 and
Disk21300.
Unit D8 is a 2-member stripeset named S7. S7 consists of Disk31300 and Disk41300.
Unit D9 is a 4-member Raidset named R5. R5 consists of Disk41400, Disk11400,
Disk21400 and Disk31400.
Disk11500, Disk21500, Disk31500, and Disk41500 are spareset members.