7. Remove the program card ESD cover (see Figure 46) and the program card,
and save them in an antistatic bag or on a grounded antistatic mat for the
replacement controller.
Figure 46: Removing the controller ESD cover
8. Disconnect all host bus cables or terminators from the controller.
Note: Use thin needle nose pliers to disconnect the cables if the extender clips are not
installed on the optical cables.
9. If connected, disconnect the PC or terminal from the controller maintenance
port.
1 Program card slot Eject button
2 Program card
3 ESD cover
5024
1
2