HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Replacing BA370, M2100 & M2200 Enclosure Elements
119HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Automatically restore the configuration by entering the following
command below if the current device configuration is saved on a disk
drive:
CONFIGURATION RESTORE
13. Determine whether configuration restore process completed successfully, and
then perform one of the following options:
Perform the following substeps if the configuration restore process did
not complete successfully:
a. Reset the PC or terminal baud rate to match the original configuration
of the controller.
b. Repeat step 10 and step 11 on page 118.
c. Proceed to the next step after a successful configuration.
Proceed to the next step if the configuration restore process completed
successfully.
14. Connect all host bus cables or terminators to the controller.
15. Mount the logical units on the host.
16. Restart the server if you are using Windows NT or Windows 2000.
17. Disconnect the PC or terminal from the controller maintenance port.
18. Install the program card ESD cover (see Figure 46 on page 116).
Replacing array controllers in dual-redundant configurations
The procedures in the following subsections apply to HSG60 and HSG80
controllers in one of the following enclosures:
HP StorageWorks BA370 enclosure
HP StorageWorks M2100 or M2200 enclosures