HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Replacing BA370, M2100 & M2200 Enclosure Elements
123HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
e. Exit VTDPY by pressing Ctrl+Y.
f. Disable Failover mode, and take the controllers out of the
dual-redundant configuration by entering the following command:
SET NOFAILOVER
3. For the controller to be replaced (), complete the following substeps:
a. Ensure that the Reset button (see Figure 45 on page 115) is a constant
green.
b. Remove the program card ESD cover (see Figure 46 on page 116).
c. Remove the program card from the controller being replaced by
pressing the program card slot Eject button (see Figure 46 on
page 116).
d. Save the ESD cover and program card in an antistatic bag or on a
grounded antistatic mat for use with the replacement controller.
4. For the operational controller, complete the following substeps:
a. Start FRUTIL by entering the following command:
RUN FRUTIL
FRUTIL automatically asks if you intend to replace the controller
cache battery.
b. Enter N(o).
The FRUTIL Main Menu is displayed (see Figure 50 and Figure 51
on page 124).
Figure 50: FRUTIL Main Menu for a controller in a BA370
FRUTIL Main Menu:
1. Replace or remove a controller or cache module
2. Install a controller or cache module
3. Replace a PVA module
4. Replace an I/O module
5. Exit
Enter choice: 1,2,3,4,5 ->