HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Replacing BA370, M2100 & M2200 Enclosure Elements
136 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
8. Note the location for each DIMM in the cache module that is being replaced,
and install the DIMMs in the corresponding locations in the replacement
cache module. Use the following substeps to remove the DIMMs:
Note: To facilitate pressing down on the DIMM retaining clips, consider using the
eraser end of a pencil or a small screwdriver.
a. Press down on the DIMM retaining clips (see Figure 58) at both ends of
the DIMM being removed.
Figure 58: Removing or installing a DIMM
b. Gently remove the DIMM from the DIMM slot, and then place the
DIMM on an antistatic bag or a grounded antistatic mat.
c. Repeat substep 8a and substep 8b for each DIMM.
d. Proceed to the “Installing cache modules in single-controller
configurations section that starts on page 137to install the DIMMs in the
replacement cache module.
1 DIMM
2 DIMM slot
3 DIMM retaining clips
5025
1
2
3